Safety is the critical issue when deciding the swing direction.
Garage fire door swing.
I am planning to install a fire door between my garage and home.
If it s one step down to the garage floor it will be ok.
The door should be a steel insulated door and the frame should be sealed as well to prevent carbon monoxide fumes from getting into your home.
Steel pre hung entry door see all.
It cannot swing out over stairs though.
The code does not specify the direction of swing for fire doors between the garage and the house.
You would need to build a landing.
Some builders have them swing inward to the garage instead of the home for safety reasons.
Typically in residential construction doors swing into the home.
Flush primed right hand inswing steel prehung front door.
There is no reason you can t swing the door out into the garage.
But in commercial they swing out for fire code.
Fire rated garage door.
Garage to home entry doors may be an exception to the inward swinging rule.
This places the hinges outside the home although this is in the garage.
If there s a fire or explosion in the garage the outward swinging door blocks damage to the interior of the home more effectively than an inward swinging door.
6 panel 90 minute fire rated primed steel prehung right hand inswing front door made of durable rust resistant galvanized steel prehung steel door includes frame for easier installation.
The reason the inspector wants to see the tag is because then they know it is a 20 minute fire rated door and meets one of the choices for type of door for garage house fire separation.
You are required to have a closer on.
Doors to individual hotel or motel units shall operate similarly except that when the bolt and unlatching operation is key operated from corridor or exterior side of the unit door large bow keys 2 inch full bow or 1 1 4 inch half bow shall be provided in lieu of lever type hardware on the corridor side.
The door needs to be outswing left handed viewing from within the home due to the meeting of 3 doors garage exterior to backyard and finished basement addition at this location in a small amount of space.
If there is a fire or explosion that occurs an outward swinging door could become a barrier to escaping the house.
Since garage doors are an exit we would install the doors to open in the path of least resistance.
It is not likely that any raised panel 1 3 8 door will ever have such a rating or qualify for proper garage house fire separation.
Openings in a wall separating a garage from the house must be protected by one of the following.